Ir directamente a la navegación principal Ir directamente a la búsqueda Ir directamente al contenido principal

Resistencia A La Compresión F’c=210 Kg/cm2 Con El Reemplazo Del Cemento En 9%, 11% Y 22% Con Vidrio Molido, Cajamarca 2023

  • Universidad Privada del Norte

Producción científica: Contribución a una revistaArtículo de la conferenciarevisión exhaustiva

Resumen

The main purpose of this research was to analyze the axial compressive strength of a concrete F'c = 210 Kg/cm2 incorporating glass as an ecological material and determine the appropriate percentage according to the evaluated. To achieve this, a partial replacement of cement was carried out with the following percentages (9%, 11% and 22%) of ground glass, in order to compare conventional or pattern concrete with an ecological concrete explained above. The study began with the analysis of the physical - mechanical properties of the aggregates that concluded with the determination of their granulometry, unit weight, moisture content, specific weight and their absorption. Next, the concrete mix was designed based on cement replacement percentages, using a 3-4" (inch) slump to ensure adequate workability of the material. A total of 72 cylindrical 6" x 12" samples were prepared using conventional concrete and replacement samples for the three percentages. The objective was to determine the optimal ground glass replacement percentage for an f'c = 210 kg/cm2. Concrete core fracture tests were performed 7, 14, and 28 days after entering the curing pit. The appropriate percentage for the mix design resulted in 11% cement replacement, as 312.64 kg/cm2 was recorded at 28 days of curing, representing a 48.88% increase in strength.

Título traducido de la contribuciónCompressive Resistance F’c=210 Kg/cm2 With The Replacement Of Cement In 9%, 11% And 22% With Ground Glass, Cajamarca 2023
Idioma originalEspañol
PublicaciónProceedings of the LACCEI international Multi-conference for Engineering, Education and Technology
N.º2025
DOI
EstadoPublicada - 2025
Evento23rd LACCEI International Multi-Conference for Engineering, Education and Technology, LACCEI 2025 - Virtual, Online
Duración: 16 jul. 202518 jul. 2025

Palabras clave

  • Axial compression
  • cement
  • cement replacement
  • cylindrical cores
  • ground glass

Huella

Profundice en los temas de investigación de 'Resistencia A La Compresión F’c=210 Kg/cm2 Con El Reemplazo Del Cemento En 9%, 11% Y 22% Con Vidrio Molido, Cajamarca 2023'. En conjunto forman una huella única.

Citar esto